Letters to a Friend, Written to Mrs. Ezra S. Carr, 1866-1879
John Muir

THE CLASSIC COLLECTION · 1902
"The Elements of Bacteriological Technique" by J. W. H. Eyre is a scientific publication written in the early 20th century. This comprehensive laboratory guide aims to equip medical, dental, and technical students with the foundation needed to conduct bacteriological research. The book covers a range of topics related to practical methods in bacteriology, including sterilization techniques, bacterial examination, and analysis methods, emphasizing the importance of personal instruction and practical application in a laboratory setting. At the start of the guide, Eyre lays out the essential laboratory regulations for handling infective materials, underscoring safety protocols designed to minimize infection risks. The opening portion also introduces the various types of glass apparatus commonly used in bacteriological work, explaining their selection and maintenance. This practical focus sets the stage for the detailed methodologies that follow, providing a solid foundation for readers who are keen to understand the intricacies of working with bacteria in a laboratory environment.
Introduction adapted from the source catalogue; source summaries may be automatically generated.
Free to read · English · 124,075 words · No account needed
MAKE TIME FOR A GOOD BOOK
On by default. Untick to stop anonymous reading totals. Each page counts after 10 seconds in view. How this works.
Anonymous counting is on unless you have switched it off.
---------------------------------+------------------------------- | TABLE III | TABLE IV Using 0.1% stock solution | Using 0.01% stock solution Third } | Fourth } dilution } + Diluent | Dilution } + Diluent | ---------------------------------+------------------------------- | 1: 1000 = 1 c.c. + 0 c.c. | 1: 10,000 = 1 c.c. + 0 c.c. 1: 1250 = 1 c.c. + 0.25 c.c. | 1: 15,000 = 1 c.c. + 0.5 c.c. 1: 1500 = 1 c.c. + 0.5 c.c. | 1: 20,000 = 1 c.c. + 1.0 c.c. 1: 1750 = 1 c.c. + 0.75 c.c. | 1: 25,000 = 1 c.c. + 1.5 c.c. 1: 2000 = 1 c.c. + 1.0 c.c. | 1: 30,000 = 1 c.c. + 2.0 c.c. 1: 2250 = 1 c.c. + 1.25 c.c. | 1: 35,000 = 1 c.c. + 2.5 c.c. 1: 2500 = 1 c.c. + 1.5 c.c. | 1: 40,000 = 1 c.c. + 3.0 c.c. 1: 2750 = 1 c.c. + 1.75 c.c. | 1: 45,000 = 1 c.c. + 3.5 c.c. 1: 3000 = 1 c.c. + 2.0 c.c. | 1: 50,000 = 1 c.c. + 4.0 c.c. 1: 3250 = 1 c.c. + 2.25 c.c. | 1: 55,000 = 1 c.c. + 4.5 c.c. 1: 3500 = 1 c.c. + 2.5 c.c. | 1: 60,000 = 1 c.c. + 5.0 c.c. 1: 3750 = 1 c.c. + 2.75 c.c. | 1: 65,000 = 1 c.c. + 5.5 c.c. 1: 4000 = 1 c.c. + 3.0 c.c. | 1: 70,000 = 1 c.c. + 6.0 c.c. 1: 4250 = 1 c.c. + 3.25 c.c. | 1: 75,000 = 1 c.c. + 6.5 c.c. 1: 4500 = 1 c.c. + 3.5 c.c. | 1: 80,000 = 1 c.c. + 7.0 c.c. 1: 4750 = 1 c.c. + 3.75 c.c. | 1: 85,000 = 1 c.c. + 7.5 c.c. 1: 5000 = 1 c.c. + 4.0 c.c. | 1: 90,000 = 1 c.c. + 8.0 c.c. --------------------------------+ 1: 95,000 = 1 c.c. + 8.5 c.c. 1: 5000 = 1 c.c. + 4.0 c.c. | 1: 100,000 = 1 c.c. + 9.0 c.c. 1: 6000 = 1 c.c. + 5.0 c.c. +----------------------------------- 1: 7000 = 1 c.c. + 6.0 c.c. | 1: 100,000 = 0.1 c.c. + 0.9 c.c. [1: 7500 = 1 c.c. + 6.5 c.c.] | 1: 200,000 = 0.1 c.c. + 1.9 c.c. 1: 8000 = 1 c.c. + 7.0 c.c. | [1: 250,000 = 0.1 c.c. + 2.4 c.c.] 1: 9000 = 1 c.c. + 8.0 c.c. | 1: 300,000 = 0.1 c.c. + 2.9 c.c. 1: 10,000 = 1 c.c. + 9.0 c.c. | 1: 400,000 = 0.1 c.c. + 3.9 c.c. ------------------------------- + 1: 500,000 = 0.1 c.c. + 4.9 c.c. 1: 10,000 = 1 c.c. + 9.0 c.c. +----------------------------------- 1: 15,000 = 1 c.c. + 14.0 c.c. | 1: 500,000 = 0.1 c.c. + 4.9 c.c. 1: 20,000 = 1 c.c. + 19.0 c.c. | 1: 600,000 = 0.1 c.c. + 5.9 c.c. 1: 25,000 = 1 c.c. + 24.0 c.c. | 1: 700,000 = 0.1 c.c. + 6.9 c.c. 1: 30,000 = 1 c.c. + 29.0 c.c. | [1: 750,000 = 0.1 c.c. + 7.4 c.c.] --------------------------------+ 1: 800,000 = 0.1 c.c. + 7.9 c.c. | 1: 900,000 = 0.1 c.c. + 8.9 c.c. | 1:1,000,000 = 0.1 c.c. + 9.9 c.c. -+-------------------------------------
---------------+--------------+---------------------+------------- Temperature | | Pounds per sq. in. | Centigrade | Mm. of Hg. | absolute pressure | Atmospheres | | | ---------------+--------------+---------------------+------------- | | | 98 deg. | 707.1 | 13.7 | 0.93 99 deg. | 733.1 | 14.2 | 0.96 100 deg. | 760.0 | 14.7 | 1.00 | | | 101 deg. | 787.8 | 15.2 | 1.03 102 deg. | 816.0 | 15.8 | 1.07 103 deg. | 845.2 | 16.3 | 1.11 104 deg. | 875.4 | 16.9 | 1.15 105 deg. | 906.4 | 17.5 | 1.19 | | | 106 deg. | 938.3 | 18.1 | 1.23 107 deg. | 971.1 | 18.8 | 1.27 108 deg. | 1004.9 | 19.4 | 1.32 109 deg. | 1039.6 | 20.1 | 1.36 110 deg. | 1075.3 | 20.8 | 1.41 | | | 111 deg. | 1112.0 | 21.5 | 1.46 112 deg. | 1149.8 | 22.2 | 1.51 113 deg. | 1188.6 | 22.9 | 1.56 114 deg. | 1228.4 | 23.7 | 1.61 115 deg. | 1269.4 | 24.5 | 1.67 | | | 116 deg. | 1311.4 | 25.3 | 1.72 117 deg. | 1354.6 | 26.2 | 1.78 118 deg. | 1399.0 | 27.0 | 1.84 119 deg. | 1444.5 | 27.9 | 1.90 120 deg. | 1491.2 | 28.8 | 1.96 | | | 121 deg. | 1539.2 | 29.7 | 2.02 122 deg. | 1588.4 | 30.7 | 2.09 123 deg. | 1638.9 | 31.7 | 2.15 124 deg. | 1690.7 | 32.7 | 2.22 125 deg. | 1743.8 | 33.7 | 2.29 ---------------+--------------+---------------------+-------------
+--------------------------+
| Temperature | |
| Centigrade | Mm. of Hg. |
+-------------+------------+
| 21 deg. | 18.4 |
| 22 deg. | 19.6 |
| 23 deg. | 20.8 |
| 24 deg. | 22.1 |
| 25 deg. | 23.5 |
| | |
| 26 deg. | 24.9 |
| 27 deg. | 26.4 |
| 28 deg. | 28.0 |
| 29 deg. | 29.7 |
| 30 deg. | 31.5 |
| | |
| 31 deg. | 33.3 |
| 32 deg. | 35.3 |
| 33 deg. | 37.3 |
| 34 deg. | 39.5 |
| 35 deg. | 41.7 |
| | |
| 36 deg. | 44.1 |
| 37 deg. | 46.6 |
| 38 deg. | 49.2 |
| 39 deg. | 51.9 |
| 40 deg. | 54.8 |
| | |
| 41 deg. | 57.8 |
| 42 deg. | 61.0 |
| 43 deg. | 64.3 |
| 44 deg. | 67.7 |
| 45 deg. | 71.3 |
| | |
| 46 deg. | 75.1 |
| 47 deg. | 79.0 |
| 48 deg. | 83.1 |
| 49 deg. | 87.4 |
| 50 deg. | 91.9 |
+-------------+------------+
For the detection of B. Tuberculosis.
Antiformin was introduced into bacteriological technique by Uhlenhuth in 1908 for the purpose of demonstrating tubercle bacilli when present in small numbers, in sputum or other material. It is a powerful oxidising agent and rapidly destroys most bacteria, but tubercle and other acid-fast organisms resist its lethal action for considerable periods, and upon this fact the method is based.
To prepare Antiformin measure out and mix:--
Your reading position is saved on this browser. Take it to another device with a library code. Reading pages adapt to text, rather than matching a printed edition.
BEHIND THE BOOK
This eBook is for the use of anyone anywhere in the United States and most other parts of the world at no cost and with almost no restrictions whatsoever. You may copy it, give it away or re-use it under the terms of the Project Gutenberg License included with this eBook or online at www.gutenberg.org. If you are not located in the United States, you will have to check the laws of the country where you are located before using this eBook. Read the source licence.
The original source file, including credits and licence, is retained by this library. Request an original-format copy at no charge. Please include the book title and Project Gutenberg identifier #27713.
KEEP YOUR CURIOSITY GOING

John Muir

Asa Gray
Asa Gray

Florence Nightingale
Elizabeth Robins Pennell
Denison Olmsted