"Hawkins Electrical Guide v. 08 (of 10)" by N. Hawkins is a technical engineering book first published in 1914. This volume is part of a groundbreaking series designed to make the complex principles of electricity accessible to the common man. Notable for its extensive detailed illustrations, the guide was published by Theodore Audel & Company—a pseudonym Hawkins used to publish his own work. The book's innovative approach to explaining emerging electrical technology established a lasting legacy in technical education.
Introduction adapted from the source catalogue; source summaries may be automatically generated.
Free to read · English · 74,999 words · No account needed
MAKE TIME FOR A GOOD BOOK
On by default. Untick to stop anonymous reading totals. Each page counts after 10 seconds in view. How this works.
Anonymous counting is on unless you have switched it off.
-------------+-----------------------------------------------------+ Temp of | STEAM PRESSURE BY GAUGE | feed water. +-----+-----+-----+-----+-----+-----+-----+-----+-----+ Deg. Fahr. | 50 | 60 | 70 | 80 | 90 | 100 | 110 | 120 | 130 | -------------+-----+-----+-----+-----+-----+-----+-----+-----+-----+ 32 |1.214|1.216|1.220|1.222|1.225|1.227|1.229|1.231|1.232| 40 |1.206|1.209|1.212|1.214|1.216|1.219|1.220|1.222|1.224| 50 |1.195|1.197|1.201|1.204|1.206|1.208|1.210|1.212|1.214| 60 |1.185|1.188|1.191|1.193|1.196|1.198|1.200|1.202|1.203| 70 |1.175|1.178|1.180|1.183|1.185|1.187|1.189|1.191|1.193| 80 |1.164|1.167|1.170|1.173|1.175|1.177|1.179|1.181|1.183| 90 |1.154|1.157|1.160|1.162|1.165|1.167|1.169|1.170|1.172| 100 |1.144|1.147|1.150|1.152|1.154|1.156|1.158|1.160|1.162| 110 |1.133|1.136|1.139|1.142|1.144|1.146|1.148|1.150|1.152| 120 |1.123|1.126|1.129|1.131|1.133|1.136|1.138|1.140|1.141| 130 |1.113|1.116|1.118|1.121|1.123|1.125|1.127|1.129|1.130| 140 |1.102|1.105|1.108|1.110|1.113|1.115|1.117|1.119|1.120| 150 |1.091|1.095|1.098|1.100|1.102|1.104|1.106|1.108|1.110| 160 |1.081|1.084|1.087|1.090|1.092|1.094|1.096|1.098|1.100| 170 |1.070|1.074|1.077|1.079|1.081|1.083|1.085|1.087|1.089| 180 |1.060|1.063|1.066|1.069|1.071|1.073|1.075|1.077|1.079| 190 |1.050|1.053|1.056|1.058|1.060|1.063|1.065|1.066|1.068| 200 |1.039|1.043|1.045|1.048|1.050|1.052|1.054|1.056|1.058| 210 |1.029|1.032|1.035|1.037|1.040|1.042|1.044|1.046|1.047| -------------+-----+-----+-----+-----+-----+-----+-----+-----+-----+ Temp of | STEAM PRESSURE BY GAUGE | feed water. +-----+-----+-----+-----+-----+-----+-----+-----+-----+ Deg. Fahr. | 140 | 150 | 160 | 170 | 180 | 190 | 200 | 210 | 220 | -------------+-----+-----+-----+-----+-----+-----+-----+-----+-----+ 32 |1.234|1.236|1.237|1.239|1.240|1.241|1.243|1.244|1.245| 40 |1.226|1.227|1.229|1.230|1.232|1.233|1.234|1.236|1.237| 50 |1.215|1.217|1.218|1.220|1.221|1.223|1.224|1.225|1.226| 60 |1.205|1.207|1.208|1.210|1.211|1.212|1.214|1.215|1.216| 70 |1.194|1.196|1.197|1.199|1.200|1.202|1.203|1.205|1.206| 80 |1.184|1.186|1.187|1.189|1.190|1.192|1.193|1.194|1.195| 90 |1.174|1.176|1.177|1.179|1.180|1.181|1.183|1.184|1.185| 100 |1.164|1.165|1.167|1.168|1.170|1.171|1.172|1.174|1.175| 110 |1.153|1.155|1.156|1.158|1.159|1.160|1.162|1.163|1.164| 120 |1.143|1.145|1.146|1.147|1.149|1.150|1.151|1.153|1.154| 130 |1.132|1.134|1.136|1.137|1.138|1.140|1.141|1.142|1.144| 140 |1.122|1.124|1.125|1.127|1.128|1.129|1.131|1.132|1.133| 150 |1.111|1.113|1.115|1.116|1.118|1.119|1.120|1.121|1.123| 160 |1.101|1.103|1.104|1.106|1.107|1.108|1.110|1.111|1.112| 170 |1.091|1.092|1.094|1.095|1.097|1.098|1.099|1.101|1.102| 180 |1.080|1.082|1.083|1.085|1.086|1.088|1.089|1.090|1.091| 190 |1.070|1.071|1.073|1.074|1.076|1.077|1.078|1.080|1.081| 200 |1.059|1.061|1.063|1.064|1.065|1.067|1.068|1.069|1.071| 210 |1.049|1.051|1.052|1.053|1.055|1.056|1.057|1.059|1.060| -------------+-----+-----+-----+-----+-----+-----+-----+-----+-----+ Temp. of | STEAM PRESSURE BY GAUGE | feed water. +-----+-----+-----+-----+-----+-----+-----+-----+-----+ Deg. Fahr. | 230 | 240 | 250 | 260 | 270 | 280 | 290 | 300 | | -------------+-----+-----+-----+-----+-----+-----+-----+----+------+ 32 |1.246|1.247|1.248|1.250|1.251|1.252|1.253|1.254| 40 |1.238|1.239|1.240|1.241|1.242|1.243|1.244|1.245| 50 |1.228|1.229|1.230|1.231|1.232|1.233|1.234|1.235| 60 |1.217|1.218|1.219|1.220|1.221|1.222|1.223|1.224| 70 |1.207|1.208|1.209|1.210|1.211|1.212|1.213|1.214| 80 |1.196|1.198|1.199|1.200|1.201|1.202|1.203|1.204| 90 |1.186|1.187|1.188|1.189|1.190|1.191|1.192|1.193| 100 |1.176|1.177|1.178|1.179|1.180|1.181|1.182|1.183| 110 |1.166|1.167|1.168|1.169|1.170|1.171|1.172|1.173| 120 |1.155|1.156|1.157|1.158|1.159|1.160|1.161|1.162| 130 |1.145|1.146|1.147|1.148|1.149|1.150|1.151|1.152| 140 |1.134|1.135|1.136|1.137|1.138|1.139|1.140|1.141| 150 |1.124|1.125|1.126|1.127|1.128|1.129|1.130|1.131| 160 |1.113|1.115|1.116|1.117|1.118|1.119|1.120|1.121| 170 |1.103|1.104|1.105|1.106|1.107|1.108|1.109|1.110| 180 |1.093|1.094|1.095|1.096|1.097|1.098|1.099|1.100| 190 |1.082|1.083|1.084|1.085|1.086|1.087|1.088|1.089| 200 |1.072|1.073|1.074|1.075|1.076|1.077|1.078|1.079| 210 |1.061|1.062|1.063|1.064|1.065|1.066|1.067|1.068| -------------+-----+-----+-----+-----+-----+-----+-----+-----+
One boiler horse power being equal to an evaporation of 34½ lbs. of water from a feed water temperature of 212° Fahr., into steam at the same temperature, the boiler capacity is accordingly
148,105 ÷ 34.5 = 4,293 boiler horse power.
The rate of evaporation is given at 8 lbs. of water (from and at 212° Fahr.), for which the fuel required is
148,105 ÷ 8 = 18,513 lbs. of coal per hour.
For a rate of combustion of 15 lbs. of coal per hour per square
foot of grate,
grate area = 18,513 ÷ 15 = 1,234 sq. ft.
For stationary boilers the usual ratio of heating surface to grate area is 35:1, accordingly the heating surface corresponding to this ratio is
1,234 × 35 = 43,190 sq.ft.
The above calculation is based on a rate of evaporation of 8 lbs. of water per lb. of coal and a rate of combustion of 15 lbs. of coal per sq. ft. of grate. For other rates the required grate area may be obtained from the following table:
---------------------------------------------------------------------- GRATE SURFACE PER HORSE POWER (KENT) ------------+------+-----+-------------------------------------------- |Pounds| | | of | Lbs.| Pounds of coal burned per square foot of |water | of | grate per hour | from | coal+----+----+----+----+----+----+----+----+---- |and at| per | | | | | | | | | | 212° | h.p.| 8 | 10 | 12 | 15 | 20 | 25 | 30 | 35 | 40 | per | per | | | | | | | | | |pound | hour+----+----+----+----+----+----+----+----+---- | of | | Square feet grate per horse power | coal | | ------------+------+-----+----+----+----+----+----+----+----+----+---- Good coal | }10 | 3.45| .43|.35 | .28| .23| .17| .14| .11| .10| .09 and boiler | } 9 | 3.83| .48| .38| .32| .25| .19| .15| .13| .11| .10 | | | | | | | | | | | Fair coal |{8.61 | 4. | .50| .40| .33| .26| .20| .16| .13| .12| .10 or boiler |{8 | 4.31| .54| .43| .36| .29| .22| .17| .14| .13| .11 |{7 | 4.93| .62| .49| .41| .33| .24| .20| .17| .14| .12 | | | | | | | | | | | Poor coal |{6.9 | 5. | .63| .50| .42| .34| .25| .20| .17| .15| .13 or boiler |{6 | 5.75| .72| .58| .48| .38| .29| .23| .19| .17| .14 |{5 | 6.9 | .86| .69| .58| .46| .35| .28| .23| .22| .17 | | | | | | | | | | | Lignite and|}3.45 |10. |1.25|1.00| .83| .67| .50| .40| .33| .29| .25 poor boiler|} | | | | | | | | | | ------------+------+-----+----+----+----+----+----+----+----+----+----
=General Arrangement of Station.=--In designing an electrical station, it is preferable that whatever rooms or divisions of the interior space are desired should determine the total outside dimensions of the plant in the original plans of the building than that these latter dimensions be fixed and the rooms, etc., be fitted in afterward.
Your reading position is saved on this browser. Take it to another device with a library code. Reading pages adapt to text, rather than matching a printed edition.

N. (Nehemiah) Hawkins
N. (Nehemiah) Hawkins

N. (Nehemiah) Hawkins

N. (Nehemiah) Hawkins
BEHIND THE BOOK
This eBook is for the use of anyone anywhere in the United States and most other parts of the world at no cost and with almost no restrictions whatsoever. You may copy it, give it away or re-use it under the terms of the Project Gutenberg License included with this eBook or online at www.gutenberg.org. If you are not located in the United States, you will have to check the laws of the country where you are located before using this eBook. Read the source licence.