"Hawkins Electrical Guide v. 08 (of 10)" by N. Hawkins is a technical engineering book first published in 1914. This volume is part of a groundbreaking series designed to make the complex principles of electricity accessible to the common man. Notable for its extensive detailed illustrations, the guide was published by Theodore Audel & Company—a pseudonym Hawkins used to publish his own work. The book's innovative approach to explaining emerging electrical technology established a lasting legacy in technical education.
Introduction adapted from the source catalogue; source summaries may be automatically generated.
Free to read · English · 74,999 words · No account needed
MAKE TIME FOR A GOOD BOOK
On by default. Untick to stop anonymous reading totals. Each page counts after 10 seconds in view. How this works.
Anonymous counting is on unless you have switched it off.
This formula (5) applies to a direct current two wire circuit, and to adapt it to any alternating current circuit it is only necessary to use the letter M instead of the number 2,160, thus
watts × feet × M
circular mils = ------------------ (6)
% loss × volts^{2}
in which M is a coefficient which has various values according to the kind of circuit and value of the power factor. These values are given in the following table:
--------+----------------------------------------------------------- | POWER FACTOR SYSTEM +-----+-----+-----+-----+-----+-----+-----+-----+-----+----- | 1.00| .98| .95| .90| .85| .80| .75| .70| .65| .60 --------+-----+-----+-----+-----+-----+-----+-----+-----+-----+----- Single |2,160|2,249|2,400|2,660|3,000|3,380|3,840|4,400|5,112|6,000 phase | | | | | | | | | | --------+-----+-----+-----+-----+-----+-----+-----+-----+-----+----- Two |1,080|1,125|1,200|1,330|1,500|1,690|1,920|2,200|2,556|3,000 phase | | | | | | | | | | (4 wire)| | | | | | | | | | --------+-----+-----+-----+-----+-----+-----+-----+-----+-----+----- Three |1,080|1,125|1,200|1,330|1,500|1,690|1,920|2,200|2,556|3,000 phase | | | | | | | | | | (3 wire)| | | | | | | | | | --------+-----+-----+-----+-----+-----+-----+-----+-----+-----+-----
NOTE.--The above table is calculated as follows: For =single phase= M = 2,160 ÷ power factor^{2} × 100; for =two phase= four wire, or three phase three wire, M = ½ (2,160 ÷ power factor^{2})× 100. Thus the value of M for a single phase line with power factor .95 = 2,160 ÷ .95^{2} × 100 = 2,400.
It must be evident that when 2,160 is taken as the value of M, formula (6) applies to a two wire direct current circuit and also to a single phase alternating current circuit when the power factor is unity.
In the table the value of M for any particular power factor is found by dividing 2,160 by the square of that power factor for single phase and twice the square of the power factor for two phase and three phase.
=Ques. For a given load and voltage how do the wires of a single and two phase system compare in size and weight, the power factor being the same in each case?=
Ans. Since the two phase system is virtually two single phase systems, the four wires of the two phase systems are half the size of the two wires of the single phase system, and accordingly, the weight is the same for either system.
+-------------------+--------------------------------------------+ | | POWER FACTOR | | SYSTEM +--------+--------+--------+--------+--------+ | | 1.00 | .98 | .90 | .80 | .70 | +-------------------+--------+--------+--------+--------+--------+ | Single phase | 1.00 | .98 | .90 | .80 | .70 | +-------------------+--------+--------+--------+--------+--------+ | Two phase, 4 wire | 2.00 | 1.96 | 1.80 | 1.60 | 1.40 | +-------------------+--------+--------+--------+--------+--------+ |Three phase, 3 wire| 1.73 | 1.70 | 1.55 | 1.38 | 1.21 | +-------------------+--------+--------+--------+--------+--------+
NOTE.--This table is for finding the value of the current in line, using the formula I = W ÷ (E × T), in which I = current in line; E = voltage between main conductors at receiving or consumers' end; W = watts. For instance, what is the current in a two phase line transmitting 1,000 watts at 550 volts, power factor .80? I = 1,000 ÷ (550 × 1.60) = 1.13.
Your reading position is saved on this browser. Take it to another device with a library code. Reading pages adapt to text, rather than matching a printed edition.

N. (Nehemiah) Hawkins
N. (Nehemiah) Hawkins

N. (Nehemiah) Hawkins

N. (Nehemiah) Hawkins
BEHIND THE BOOK
This eBook is for the use of anyone anywhere in the United States and most other parts of the world at no cost and with almost no restrictions whatsoever. You may copy it, give it away or re-use it under the terms of the Project Gutenberg License included with this eBook or online at www.gutenberg.org. If you are not located in the United States, you will have to check the laws of the country where you are located before using this eBook. Read the source licence.
The original source file, including credits and licence, is retained by this library. Request an original-format copy at no charge. Please include the book title and Project Gutenberg identifier #50068.
KEEP YOUR CURIOSITY GOING

Charles G. (Charles Griffith) Ross
Hannah Webster Foster

Emily Lawless
Edwin Hamlin Carr

Charles De Lano Hine
Andrew Ure