
Pumps and Hydraulics, Part 2 (of 2)
N. (Nehemiah) Hawkins

THE CLASSIC COLLECTION · 1914
"Hawkins Electrical Guide v. 04 (of 10)" by N. Hawkins is a technical engineering book first published in 1914. This volume is part of a groundbreaking series designed to explain complex electrical principles to ordinary readers. Notable for its extensive detailed illustrations, the guide made the emerging technology of electricity accessible to the common person. The work became foundational content for decades of subsequent technical publications under the Audels brand name.
Introduction adapted from the source catalogue; source summaries may be automatically generated.
Free to read · English · 72,766 words · No account needed
MAKE TIME FOR A GOOD BOOK
On by default. Untick to stop anonymous reading totals. Each page counts after 10 seconds in view. How this works.
Anonymous counting is on unless you have switched it off.
[4] =CAUTION.=—The size thus obtained should be compared with the table of carrying capacity of wires as given on page 731 to see if the wires would have to carry more than the allowable current.
===================+======================================================= VOLTS | PERCENTAGE OF LOSS ===================+======================================================= 2000 | 1.7 1.5 1.4 1.2 1.1 1.0 0.75 0.5 1000 | 3.4 2.9 2.7 2.4 2.2 2.0 1.5 1.0 500 | 6.5 5.7 6.2 4.8 4.3 3.9 2.9 2.0 220 | 13.7 12.0 11.0 10.3 9.3 8.3 6.5 4.4 110 | — — 20.0 18.5 17.0 15.4 12.0 8.4 52 | — — — — — — 22.4 16.1 ===================+======================================================= ACTUAL VOLTS LOST =========+=========+======================================================= Carrying | | Capacity | Size | 35 30 27.5 25 22.5 20 15 10 Amperes. | B. & S. | =========+=========+======================================================= 300 | 0000 | 345800 296400 271700 247000 222300 197600 148200 98800 245 | 000 | 274400 235200 215600 196000 176400 156800 117600 78400 215 | 00 | 217525 186450 170912 155375 139837 124300 93225 62150 190 | 0 | 172550 147900 135575 123250 110925 98600 73950 49300 160 | 1 | 136850 117300 107525 97750 87975 78200 58650 39100 135 | 2 | 108500 93000 85250 77500 69750 62000 46500 31000 115 | 3 | 86100 73800 67650 61500 55350 49200 36900 24600 100 | 4 | 68250 58500 53625 48750 43875 39000 29250 19500 90 | 5 | 54250 46500 42625 38750 34875 31000 23250 15500 80 | 6 | 43050 36900 33825 30750 27675 24600 18450 12300 60 | 8 | 26965 23130 21202 19275 17347 15420 11565 7710 40 | 10 | 16975 14550 13337 12125 10912 9700 7275 4850 30 | 12 | 10675 9150 8388 7625 6862 6100 4575 3050 22 | 14 | 6720 5760 5280 4800 4320 3840 2880 1920 5[5] | 16 | 4235 3630 3328 3025 2723 2420 1815 1210 ————————-+————————-+——————————————————————————————————————————————————————-
===================+===================================================== VOLTS | PERCENTAGE OF LOSS ===================+===================================================== 2000 | 0.45 0.4 0.35 0.3 0.25 0.2 0.15 0.1 0.05 1000 | 0.9 0.8 0.7 0.6 0.5 0.4 0.3 0.2 0.1 500 | 1.8 1.6 1.4 1.2 1.0 0.8 0.6 0.4 0.2 220 | 3.9 3.5 3.1 2.7 2.2 1.8 1.4 0.9 0.45 110 | 7.6 6.8 6.0 5.2 4.4 3.5 2.7 1.8 0.9 52 | 14.7 13.3 11.8 10.3 8.8 7.1 5.5 3.7 1.9 ===================+===================================================== ACTUAL VOLTS LOST =========+=========+===================================================== Carrying | | Capacity | Size | 9 8 7 6 5 4 3 2 1 Amperes. | B. & S. | =========+=========+===================================================== 300 | 0000 | 88920 79040 69160 59280 49400 39520 29640 19760 9880 245 | 000 | 70560 62720 54880 47040 39200 31360 23520 15680 7840 215 | 00 | 55935 49720 43505 37290 31075 24860 18645 12430 6215 190 | 0 | 44370 39440 34510 29580 24650 19720 14790 9860 4930 160 | 1 | 35190 31280 27370 23460 19550 15640 11730 7820 3910 135 | 2 | 27900 24800 21700 18600 15500 12400 9300 6200 3100 115 | 3 | 22140 19680 17220 14760 12300 9840 7380 4920 2460 100 | 4 | 17550 15600 13650 11700 9750 7800 5850 3900 1950 90 | 5 | 13950 12400 10850 9300 7750 6200 4650 3100 1550 80 | 6 | 11070 9840 8610 7380 6150 4920 3690 2460 1230 60 | 8 | 6939 6168 5397 4626 3855 3084 2313 1542 771 40 | 10 | 4365 3880 3395 2910 2425 1940 1455 970 486 30 | 12 | 2745 2440 2135 1830 1525 1220 915 610 305 22 | 14 | 1728 1536 1344 1152 960 768 576 384 192 5[5] | 16 | 1089 968 847 726 605 484 363 242 121 ————————-+————————-+————————————————————————————————————————————————————-
[5] NOTE.—In case a larger loss than any given in the table is required, proceed as follows:—Divide the ampere feet by 10 and then refer to column of Actual Volts Lost divided by 10, from which the size of wire is found as before.
RULE.—Multiply current in amperes by single distance and refer to the nearest corresponding number under column of actual volts lost, to find size of wire. It should also be noted that the underwriters prohibit the use of wire smaller than No. 14 B. & S. gauge, except as allowed for fixture work and pendant cord.
GAUGE NUMBER OF WIRES B. & S. 2 4 8 16 32 64 128 256 512 1024 2048 4096 8192 16384
0000 0 3 6 9 12 15 18 21 24 27 30 33 36 39
000 1 4 7 10 13 16 19 22 25 28 31 34 37 40
____
00 2 5 8 11 14 17 20 23 26 29 32 35 38| 0+6
0 3 6 9 12 15 18 21 24 27 30 33 36 39| 1+7
1 4 7 10 13 16 19 22 25 28 31 34 37 40| 2+8
___|
2 5 8 11 14 17 20 23 26 29 32 35 38|3+9 4+6
3 6 9 12 15 18 21 24 27 30 33 36 39|4+10 5+7
4 7 10 13 16 19 22 25 28 31 34 37 40|5+11 6+8
___|
5 8 11 14 17 20 23 26 29 32 35 38|6+12 7+9
6 9 12 15 18 21 24 27 30 33 36 39|7+13 8+10
7 10 13 16 19 22 25 28 31 34 37 40|8+14 9+11
___|
8 11 14 17 20 23 26 29 32 35 38|9+15 10+12
9 12 15 18 21 24 27 30 33 36 39|10+16 11+13
10 13 16 19 22 25 28 31 34 37 40|11+17 12+14
___|
11 14 17 20 23 26 29 32 35 38|12+18 13+15
12 15 18 21 24 27 30 33 36 39|13+19 14+16
13 16 19 22 25 28 31 34 37 40|14+20 15+17
__|
14 17 20 23 26 29 32 35 38|15+21 16+18
15 18 21 24 27 30 33 36 39|16+22 17+19
16 19 22 25 28 31 34 37 40|17+23 18+20
__|
17 20 23 26 29 32 35 38|18+24 19+21
18 21 24 27 30 33 36 39|19+25 20+22
19 22 25 28 31 34 37 40|20+26 21+23
__|
20 23 26 29 32 35 38|21+27 22+24
21 24 27 30 33 36 39|22+28 23+25
22 25 28 31 34 37 40|23+29 24+26
__|
23 26 29 32 35 38|24+30 25+27
24 27 30 33 36 39|25+31 26+28
25 28 31 34 37 40|26+32 27+29
__|
26 29 32 35 38|27+33 28+30
27 30 33 36 39|28+34 29+31
28 31 34 37 40|29+35 30+32
__|
29 32 35 38|30+36 31+33
30 33 36 39|31+37 32+34
31 34 37 40|32+38 33+35
__|
32 35 38|33+39 34+36
33 36 39|34+40 35+37
34 37 40|36+39
__|
35 38|37+39
36 39|38+40
37 40|
=Ques. If the calculated size of wire be larger than any in the table how is the required area obtained?=
Ans. By using two or more smaller wires in parallel, whose combined area is equal to the required area.
To facilitate finding the equivalent sizes the above table of wire equivalents has been prepared.
=Ques. How is the table of wire equivalents used?=
Ans. To use the table, find in the vertical column at left the size of conductor desired; then follow along horizontally until the size of wire that is desired to use for the strands, and the corresponding number at top of column will give the number of strands of that size wire required.
=Ques. What is the significance of the zig-zag line?=
Ans. The figures below this line give the gauge numbers of two wires which will have the same conductivity as the corresponding conductor in left hand column.
=Incandescent Lamps on 660 Watt Circuits.=—The standard incandescent lamp is rated as equivalent to the light given by 16 candles, and may consume, according to type and make, from 50 to 56 watts, or from 3.1 to 3.5 watts per candle power. Therefore, a 660 watt circuit will carry thirteen 16 candle power 49.6 watt lamps, or eleven 56 watt lamps.
Your reading position is saved on this browser. Take it to another device with a library code. Reading pages adapt to text, rather than matching a printed edition.

N. (Nehemiah) Hawkins
N. (Nehemiah) Hawkins

N. (Nehemiah) Hawkins

N. (Nehemiah) Hawkins
BEHIND THE BOOK
This eBook is for the use of anyone anywhere in the United States and most other parts of the world at no cost and with almost no restrictions whatsoever. You may copy it, give it away or re-use it under the terms of the Project Gutenberg License included with this eBook or online at www.gutenberg.org. If you are not located in the United States, you will have to check the laws of the country where you are located before using this eBook. Read the source licence.
The original source file, including credits and licence, is retained by this library. Request an original-format copy at no charge. Please include the book title and Project Gutenberg identifier #49512.
KEEP YOUR CURIOSITY GOING

Charles G. (Charles Griffith) Ross
Hannah Webster Foster

Emily Lawless
Edwin Hamlin Carr

Charles De Lano Hine
Andrew Ure