"Electric Transmission of Water Power" by Alton D. Adams is a scientific publication written in the early 20th century. The work delves into the complexities and practicalities of using water-power for generating electrical energy and its distribution across varying distances, highlighting the advancements in electrical engineering. It likely targets those interested in electrical systems, engineering principles, and the historical context of energy transmission. The opening of the book provides an overview of the integration of electrical systems derived from water-power into major North American cities, detailing how these systems operate over extensive distances. Adams outlines numerous water-power stations and their capabilities, emphasizing the significant role of water power in supplying electricity to urban centers while illustrating the implications for energy costs and competition with other energy sources such as coal and gas. The narrative sets the stage for a deeper exploration of electric power transmission methodologies and the economic considerations associated with different generation systems.
Introduction adapted from the source catalogue; source summaries may be automatically generated.
Free to read · English · 112,520 words · No account needed
MAKE TIME FOR A GOOD BOOK
On by default. Untick to stop anonymous reading totals. Each page counts after 10 seconds in view. How this works.
Anonymous counting is on unless you have switched it off.
Sag in lines, 309
St. Hyacinthe (Que.) plant, 118
St. Joseph plant, 66
St. Maurice plant (Switzerland), 31
Salem (N. C.) plant, 121, 122
San Gabriel Cañon plant, 26, 27, 28, 208
Santa Ana plant, 1, 26, 27, 28, 74, 76, 82, 83, 92, 94, 95, 96, 97,
98, 99, 101, 102, 208, 245, 263, 280, 281, 294, 295, 296
Sault Ste. Marie plant, 72, 83, 85, 89, 97, 102, 104, 105, 112, 113,
117, 118, 120, 127
Scott system, 132
Series distribution, 167
machines, 41
Sewall’s Falls plant, 26, 27, 28, 155
Shawinigan Falls plant, 1, 70, 71, 107, 116, 117, 163, 164, 166, 209,
212, 213, 235, 236, 242, 245, 267, 272, 273, 280, 282, 294, 295, 296
Sheaths for cables, 194
Shunted air-gaps, 185
Skin effect, 206, 232
Snoqualmie Falls plant, 3, 4
map of transmission lines, 4
Snow, 293
Soldered joints, 206
Spacing of poles, 249
of wire, 234
Spans, long, 190, 250
strains for different lengths, 324
Sparking distances, 182
voltages, 182
Speed, peripheral, of impulse wheels, 108
peripheral of turbines, 85, 103
regulation, 38, 42
d. c. motors, 38
Spier Falls plant, 1, 2, 3, 54, 58, 61, 62, 68, 91, 94, 98, 124, 126,
127, 130, 141, 142, 146, 161, 174, 236, 237, 243, 244, 245, 250, 253,
266, 280, 285, 287, 289, 291, 294, 295, 296, 312
Star connection, 131
Static discharges, 170
Steam and water-power station combined, 84
electric plant, cost of labor, 12
cost of operation, 12
floor area per k. w., 102
vs. water-power, 5
Steel towers, 306
Storage capacity, 15
Strains on insulation as affected by resistance in series with
arrester, 185
Stray currents, protection against, 195
Submarine cables, 187, 192, 194
Sub-station, arrangement of apparatus, 128
Sub-stations, 157, 237
Surges, 136
Switchboard, 156
wiring, 146, 148, 149
Switches, 135, 244
arcing of, 135
electrically operated, 140
long break, 135
oil, 136
open-air, 136
pneumatically operated, 140
power operated, 138
relay, 145
Switch-houses, 141, 142, 238, 244
Switching, 146
high-tension, 147
Synchronous converters, 115
cost, 117
motors, 165, 241
Tail-race, 96
Telephone, 161
Telluride plant, 47, 160, 169, 181
Temperature of cables, 198
rise in conduits, 198
Tensile strength of conductor metals, 201
Time-limit circuit-breaker, 152
Time relays, 152, 153
Towers, 250, 306
angle, 320
cost, 310
dimensions, 314
erection of, 316-319
heavy, 320
reliability of operation, 311
spans, 313
steel, cost, 307, 308
steel pins, 312
strain on, 324
Transformers, 122
air-blast vs. water-cooled, 129
artificially cooled, 129
at sub-stations, 125
blower capacity necessary to cool, 130
constant-current, 167
cooling, quantity of water necessary, 129
cost, 21, 116, 124, 134
cost of operation, 129
cost of, relative, 20
delta and star connections, 131
efficiency, 133
frequency, effect of, 116
insulation, 45
in transmission systems, 134
limiting voltage for, 32
location of, 97
polyphase, 124
regulation, 125
reserve, 149
secondary, in series, 131
single-phase, 124
two- to three-phase, 132
used to compensate drop, 133
used to regulate voltage, 162
voltages, 45
when to use, 122
Transmission, constant-current, 38, 216
constant-voltage, 40, 217
continuous-current, 31, 32
control equipment, 35
cost of, 19, 40, 222
(d. c.) cost of, 40
efficiency, 35, 41
first long line, 37
frequency, 113
generator end, 103
lightning protection, 34
limiting voltage, 44
lines, arcing, 46
calculation of, 221-232
charging current, 197
construction, 222
cost, 310
cross-arms, 49, 256
crossings, 187, 190
data from various plants, 245
effect of length on cost, 20
effect of length on cost of power, 24
efficiency, 22, 24
end strain at entries, 325
entrance to buildings, 179, 261
inductance, 206
induction, 168
insulation, 34
insulators (see Insulators), 287
insulator-pins (see Pins), 270
interest, maintenance and depreciation, 22
leakage, 47, 207, 214
length of, capacity of, population supplied, 8
lightning arresters (see Lightning Arresters), 179
lightning protection, 118
long spans, 190
loss, 22, 39
losses, 215
maximum investment in, 220
method of fastening conductors to insulators, 323
operation, 311
pole spacing, 249
regulation with synchronous motors, 241
relative weights of three-phase, two-phase, and single-phase, 228
right-of-way, 246
sag in, 309
spacing of wire, 234
steel towers (see Towers), 306
switch-houses, 238
switches, fuses, and circuit-breakers, 135
take up, arrangement for, 325
total cost of, 22
total cost of operation, 23
transposition of wires, 206, 314
voltage, 21, 215
in cables, 190
regulation, 130
wind pressure, 210
long line, 221
minimum-sized wire, 202
physical limits of, 44
a. c. pole line construction, 34
d. c. pole line construction, 33
pole lines, 246
problems, 19
regulation, 155, 239
selection of circuits, 233
single vs. parallel circuits, 241
spacing of conductors, 46
submarine, 187
three-phase, 113
three-phase and two-phase, 228
two-phase, 113
underground, 187
without step-up transformers, 120
Transposition of wires, 206
Turbines, high-speed, 107
horizontal, 79, 83, 89, 97
impulse, 82, 90, 99
speed of, 108
low-head good speed, 105
peripheral, speed of, 85, 103
pressure, 79
several on same shaft, 85, 105
vertical, 79, 84, 85, 86, 97
Your reading position is saved on this browser. Take it to another device with a library code. Reading pages adapt to text, rather than matching a printed edition.
BEHIND THE BOOK
This eBook is for the use of anyone anywhere in the United States and most other parts of the world at no cost and with almost no restrictions whatsoever. You may copy it, give it away or re-use it under the terms of the Project Gutenberg License included with this eBook or online at www.gutenberg.org. If you are not located in the United States, you will have to check the laws of the country where you are located before using this eBook. Read the source licence.
The original source file, including credits and licence, is retained by this library. Request an original-format copy at no charge. Please include the book title and Project Gutenberg identifier #48134.
KEEP YOUR CURIOSITY GOING

Charles G. (Charles Griffith) Ross
Hannah Webster Foster

Emily Lawless
Edwin Hamlin Carr

Charles De Lano Hine
Andrew Ure