The Writing of News A Handbook with Chapters on Newspaper Correspondence and Copy Reading
Charles G. (Charles Griffith) Ross
THE CLASSIC COLLECTION · 1908
"A Manual of Clinical Diagnosis" by James Campbell Todd is a scientific publication written in the early 20th century. The book serves as a practical guide aimed at students and practitioners in the field of medicine, focusing on important laboratory methods and their interpretations for clinical diagnosis. It emphasizes simplicity in methods and their clinical applicability, providing a wealth of illustrations to support understanding. The opening of the manual introduces the purpose of the text, outlining its foundation in the author's teaching notes designed for classes. Todd emphasizes the importance of clear and concise laboratory procedures, particularly for the novice practitioner. He discusses the critical role of the microscope in clinical diagnostics, offering guidelines on its proper use, including illumination, focusing, magnification, and care, which are essential for accurate examination. The initial chapter on sputum analysis begins to explain the parameters for effective clinical evaluation, highlighting the significance of both physical and microscopic examinations in diagnosing various respiratory diseases.
Introduction adapted from the source catalogue; source summaries may be automatically generated.
Free to read · English · 65,654 words · No account needed
MAKE TIME FOR A GOOD BOOK
On by default. Untick to stop anonymous reading totals. Each page counts after 10 seconds in view. How this works.
Anonymous counting is on unless you have switched it off.
Quantitative Estimation.--The gravimetric, which is the most reliable method, is too elaborate for clinical work. Both Esbach's, which is very widely used, and the centrifugal method give fair results.
(1) Esbach's Method.--The urine must be clear, of acid reaction, and not concentrated. Always filter before testing, and, if necessary, add acetic acid and dilute with water. Esbach's tube (Fig. 23) is essentially a test-tube with a mark U near the middle, a mark R near the top, and graduations ½, 1, 2, 3, etc., near the bottom. Fill the tube to the mark U with urine and to the mark R with the reagent. Close with a rubber stopper, invert slowly several times, and set aside in a cool place. At the end of twenty-four hours read off the height of the precipitate. This gives the amount of albumin in grams per liter, and must be divided by 10 to obtain the percentage.
Esbach's reagent consists of picric acid, 1 gm., citric acid, 2 gm., and distilled water, to make 100 c.c.
(2) Purdy's Centrifugal Method.--This is detailed in the accompanying table. The percentage by weight is approximately one-fiftieth of the bulk percentage.
Table showing the relation between the volumetric and gravimetric percentage of albumin obtained by means of the centrifuge with radius of six and three-quarter inches; rate of speed, 1500 revolutions per minute; time, three minutes.
VOLUMETRIC | PERCENTAGE BY | GRAINS PER
PERCENTAGE BY | WEIGHT OF | FLUIDOUNCE
CENTRIFUGE. | DRY ALBUMIN. | DRY ALBUMIN.
--------------+---------------+-------------
¼ | 0.005 | 0.025
½ | 0.01 | 0.05
¾ | 0.016 | 0.075
1 | 0.021 | 0.1
1¼ | 0.026 | 0.125
1½ | 0.031 | 0.15
1¾ | 0.036 | 0.175
2 | 0.042 | 0.2
2¼ | 0.047 | 0.225
2½ | 0.052 | 0.25
2¾ | 0.057 | 0.275
3 | 0.063 | 0.3
3¼ | 0.068 | 0.325
3½ | 0.073 | 0.35
3¾ | 0.078 | 0.375
4 | 0.083 | 0.4
4¼ | 0.089 | 0.425
4½ | 0.094 | 0.45
4¾ | 0.099 | 0.475
5 | 0.104 | 0.5
5½ | 0.111 | 0.55
6 | 0.125 | 0.6
6½ | 0.135 | 0.65
7 | 0.146 | 0.7
7½ | 0.156 | 0.75
8 | 0.167 | 0.8
8½ | 0.177 | 0.85
9 | 0.187 | 0.9
9½ | 0.198 | 0.95
10 | 0.208 | 1.0
10½ | 0.219 | 1.05
11 | 0.229 | 1.1
11½ | 0.24 | 1.15
12 | 0.25 | 1.2
12½ | 0.26 | 1.25
13 | 0.271 | 1.3
13½ | 0.281 | 1.35
14 | 0.292 | 1.4
14½ | 0.302 | 1.45
15 | 0.313 | 1.5
15½ | 0.323 | 1.55
16 | 0.333 | 1.6
16½ | 0.344 | 1.65
17 | 0.354 | 1.7
17½ | 0.365 | 1.75
18 | 0.375 | 1.8
18½ | 0.385 | 1.85
19 | 0.396 | 1.9
19½ | 0.406 | 1.95
20 | 0.417 | 2.0
20½ | 0.427 | 2.05
21 | 0.438 | 2.1
21½ | 0.448 | 2.15
22 | 0.458 | 2.2
22½ | 0.469 | 2.25
23 | 0.479 | 2.3
23½ | 0.49 | 2.35
24 | 0.5 | 2.4
24½ | 0.51 | 2.45
25 | 0.521 | 2.5
25½ | 0.531 | 2.55
26 | 0.542 | 2.6
26½ | 0.552 | 2.65
27 | 0.563 | 2.7
27½ | 0.573 | 2.75
28 | 0.583 | 2.8
28½ | 0.594 | 2.85
29 | 0.604 | 2.9
29½ | 0.615 | 2.95
30 | 0.625 | 3.0
30½ | 0.635 | 3.05
31 | 0.646 | 3.1
31½ | 0.656 | 3.15
32 | 0.667 | 3.2
32½ | 0.677 | 3.25
33 | 0.687 | 3.3
33½ | 0.698 | 3.35
34 | 0.708 | 3.4
34½ | 0.719 | 3.45
35 | 0.729 | 3.5
35½ | 0.74 | 3.55
36 | 0.75 | 3.6
36½ | 0.76 | 3.65
37 | 0.771 | 3.7
37½ | 0.781 | 3.75
38 | 0.792 | 3.8
38½ | 0.801 | 3.85
39 | 0.813 | 3.9
39½ | 0.823 | 3.95
40 | 0.833 | 4.0
40½ | 0.844 | 4.05
41 | 0.854 | 4.1
41½ | 0.865 | 4.15
42 | 0.875 | 4.2
42½ | 0.885 | 4.25
43 | 0.896 | 4.3
43½ | 0.906 | 4.35
44 | 0.917 | 4.4
44½ | 0.927 | 4.45
45 | 0.938 | 4.5
45½ | 0.948 | 4.55
46 | 0.958 | 4.6
46½ | 0.969 | 4.65
47 | 0.979 | 4.7
47½ | 0.99 | 4.75
48 | 1.0 | 4.8
Test.--Three cubic centimeters of 10 per cent. solution of ferrocyanid of potassium and 2 cubic centimeters of 50 per cent. acetic acid are added to 10 cubic centimeters of the urine in the percentage tube and stood aside for ten minutes, then placed in the centrifuge and revolved at rate of speed and time as stated at head of the table. If albumin is excessive, dilute the urine with water until volume of albumin falls below 10 per cent. Multiply result by the number of dilutions employed before using the table.
{76} (2) Mucin (Nucleo-albumin).--Traces of the substances which are loosely classed under this name are present in normal urine; increased amounts are observed in irritations and inflammations of the mucous membrane of the urinary tract. They are of interest chiefly because they may be mistaken for albumin in most of the tests. If the urine be diluted with water and acidified with acetic acid, the appearance of a white cloud indicates the presence of mucin.
Your reading position is saved on this browser. Take it to another device with a library code. Reading pages adapt to text, rather than matching a printed edition.
BEHIND THE BOOK
This eBook is for the use of anyone anywhere in the United States and most other parts of the world at no cost and with almost no restrictions whatsoever. You may copy it, give it away or re-use it under the terms of the Project Gutenberg License included with this eBook or online at www.gutenberg.org. If you are not located in the United States, you will have to check the laws of the country where you are located before using this eBook. Read the source licence.
The original source file, including credits and licence, is retained by this library. Request an original-format copy at no charge. Please include the book title and Project Gutenberg identifier #47078.
KEEP YOUR CURIOSITY GOING

Charles G. (Charles Griffith) Ross
Hannah Webster Foster

Emily Lawless
Edwin Hamlin Carr

Charles De Lano Hine
Andrew Ure